Limitations on Use: the Gyrolab workstation, software and its consumables are sold for Research Use Only.
| Instrument | Contents/Description |
Product number |
| Gyrolab xP | Includes Gyrolab xP workstation, Gyrolab Control Unit (Windows Professional XP SP3 and softwares Microsoft® Excel®, Gyrolab Control and Gyrolab Evaluator pre-installed), degasser, wash bottles and tubings, USB-stick 1 GB, start-up kit for sample handling (microplates (25), microplate foils (50), microplate foil adapter (1)), User Manuals (Gyrolab Instrument- , User- and Quick- Guides). 12 months warranty. Excludes cost for installation. |
P0004943 |
| Gyrolab Bioaffy consumables | Contents/Description |
Product number |
| Gyrolab Bioaffy 1000* | 1 Gyrolab Bioaffy CD microlaboratory, 1000 nL sample volume, 96 microstructures. |
P0004253 |
| Gyrolab Bioaffy 200* | 1 Gyrolab Bioaffy CD microlaboratory, 200 nL sample volume, 112 microstructures. |
P0004180 |
| Gyrolab Bioaffy 20 HC* | 1 Gyrolab Bioaffy CD microlaboratory, 20 nL sample volume, 112 microstructures. |
P0004424 |
| Rexxip A | 25 mL, 1 x standard formulation. Buffer of choice unless analytes are positively charged or hydrophobic or if heterophilic antibodies are present in the sample. |
P0004820 |
| Rexxip A-max | 25 mL, 2 x standard formulation. Buffer of choice unless analytes are positively charged or hydrophobic or if heterophilic antibodies are present in the sample. |
P0004821 |
| Rexxip AN | 25 mL, 1 x standard formulation, increased ionic strength. For positively-charged analytes. |
P0004994 |
| Rexxip AN-max | 25 mL, 2 x standard formulation, increased ionic strength. For positively-charged analytes. |
P0004995 |
| Rexxip H | 25 mL, 1 x standard formulation, agents to neutralize heterophilic antibodies. For samples containing heterophilic antibodies (e.g. human or cyno samples) and where the assay format (Ab/Ab) could cause false positives. |
P0004822 |
| Rexxip H-max | 25 mL, 2 x standard formulation, agents to neutralize heterophilic antibodies. For samples containing heterophilic antibodies (e.g. human or cyno samples) and where the assay format (Ab/Ab) could cause false positives. |
P0004823 |
| Rexxip HN | 25 mL, 1 x standard formulation, agents to neutralize heterophilic antibodies, increased ionic strength. For positively-charged analytes. |
P0004996 |
| Rexxip HN-max | 25 mL, 2 x standard formulation, agents to neutralize heterophilic antibodies, increased ionic strength. For positively-charged analytes. |
P0004997 |
| Rexxip HX | 25 mL, 2 x standard formulation 3, agents to neutralize heterophilic antibodies, suitable for human GLP-1 with potential for use with other negatively-charged analytes |
P0020033 |
| Rexxip HX-max | 25 mL, 2 x standard formulation 3, agents to neutralize heterophilic antibodies, suitable for human GLP-1 with potential for use with other negatively-charged analytes |
P0004997 |
| Rexxip CCS | 25 mL, 1 x standard formulation 2. For cell culture samples. |
P0004824 |
| Rexxip F | 10 mL, 1 x standard formulation, detergent A. For dilution of detection reagent and suitable for hydrophobic analytes. |
P0004825 |
* Orders can be placed for up to 500 CDs from a single batch. Contact your local representative for details.
| Gyrolab ADA consumables | Contents/Description |
Product number |
| Gyrolab ADA CD* | 1 Gyrolab ADA CD microlaboratory, 200 nL sample volume, 48 microstructures. Requires software module Gyrolab ADA Software. |
P0020026 |
| Rexxip ADA | 25 mL, 1 x standard formulation 3, detergent A. For dilution of samples and controls when using Gyrolab ADA CDs. |
P0020027 |
* Orders can be placed for up to 500 CDs from a single batch. Contact your local representative for details.
| Accessories | Contents/Description |
Product number |
| PCR Plate 96 | Pack of 25. To hold samples and reagents for processing within a Gyrolab workstation. |
P0004861 |
| Microplate foil | Pack of 50. For sealing of microplates. |
P0003313 |
| Microplate foil adapter | One (1) adapter for transfer of microplate foil to microplates. |
P0003697 |
| Gyrolab User Licenses | For 5 additional users. Includes a certificate. |
P0004955 |
| Software modules | Contents/Description |
Product number |
| Gyrolab Viewer | Provides access to binding profiles of each data point directly from within Gyrolab Evaluator. Software module compatible with Gyrolab Control v 5.3 or higher and Gyrolab Evaluator v 3.2 or higher. Includes Instruction For Use and software licence for one instrument. |
P0020028 |
| Gyrolab ADA Software | Enables analysis of anti-drug antibodies using Gyrolab ADA CDs. Supports ADA assay workflow through development and validation to screening and confirmatory analysis. Software module is compatible with Gyrolab Control v 5.4 or higher and Gyrolab Evaluator v 3.3 or higher. Includes Instruction For Use, software licence for one instrument, Gyrolab ADA assay protocol, instrument re-validation by Gyros-certified service engineer and one day training by Gyros-certified application specialist. |
P0020025 |
| Gyrolab LIMS Interface | Integrates Gyrolab workstation into a LIMS workflow. Software module compatible with Gyrolab Control v 5.2 or higher. Includes Instruction For Use, software licence for one instrument and support to cover the LIMS connection. |
P0005028 |
| Gyrolab Control Report | Enables automatic generation of 21 CFR Part 11 compliant, non-editable, raw data report after each run. Software module compatible with Gyrolab Control v 5.3 or higher. Includes Instruction For Use and software licence for one instrument. |
P0020006 |
| Gyrolab Serial Dilution Analysis | Enables automatic evaluation of spike recovery in order to verify accuracy of sample analysis. Software module compatible with Gyrolab Evaluator v 3.2 or higher. Includes Instruction For Use, one (1) installation CD kit, one (1) hour webinar training by a Gyros Field Application Specialist. Installation is performed by the user. |
P0005016 |
| Performance and validation support | Contents/Description |
Product number |
| Gyrolab Functionality Check Kit* | A confirmatory test of instrument performance compatible with Gyrolab Control v 5.2. Includes Functionality Check CD (1), reagent (1500 μL), wash buffer (1500 μL), microplates and foils (2 of each), instruction for use (1). The kit is designed for one time use with the ability to repeat the check in the event that the the first check does not pass following a trouble shooting procedure. |
P0005002 |
| IQ/OQ validation support and PQ guidance | Documented collection of procedures and test protocols for on-site installation, operational and guidance for performance qualification. Gyros-certified engineer performs IQ/OQ over approximately 3-4 days. Includes documented procedures on how to perform PQ. |
P0003807 |
* If ordering Gyrolab Functionality Check Kits, contact your local representative for details of discounts available on orders for six or more kits.
| Service contract | Contents/Description |
Product number |
| GOLD PLUS Service contract | Costs covered: spare parts, on-site repairs, travel, labor, lodging costs for non-PM service visit. Routine hardware/software updates. Phone or email support for instrument networking. Software upgrades installed during PM or other scheduled service visit. Instrument revalidation – performed after software or hardware updates and upgrades or instrument relocation. |
P0020004 |
| GOLD Service contract | Costs covered: spare parts, on-site repairs, travel, labor, lodging costs for non-PM service visit. Routine hardware/software updates. Phone or email support for instrument networking free of charge up to 8 h. |
P0020003 |
| SILVER Service Contract | Costs covered: 10% discount on spare parts. Routine hardware/software updates. Phone or email support for instrument networking free of charge up to 4 h. |
P0020002 |
| Training and Application Support | Contents/Description |
Product number |
| Basic Training Course | Introductory course. Excludes costs for travel and accommodation for Gyros-certified Application Specialist. Approximately 2.5 days for up to 3 attendees at user site or a Gyros facility. |
P0004417 |
| Advanced Training Course | Advanced course for user holding a certificate from the Basic Training course. Excludes costs for travel and accommodation for Gyros-certified Application Specialist. Approximately 2.5 days for up to 3 attendees at user site or a Gyros facility. |
P0004525 |
| Field Application Specialist Support | Gyros-certified Application Specialist to assist with assay development or other issues related to running immunoassays on a Gyrolab workstation. Time and costs determined per project. |
P0004526 |
Extract from Gyros delivery and payment terms, for full version see Terms and Conditions: • Consumables are delivered within 10 working days after order • Instrument is delivered according to order acknowledgement • Payments are due within 30 days net after delivery